智(zhi)能(neng)温湿度控制,实现①加(jia)热(re)除湿,②加(jia)热(re)加(jia)湿,③降温除湿,④降温加(jia)湿控(kong)(kong)制,进(jin)口瑞士STH10高精度传感器芯(xin)片(pian),进(jin)口芯(xin)片(pian),稳(wen)定性高,两路30A大(da)电(dian)流继电(dian)器,可(ke)直接控(kong)(kong)制4KW以下(xia)设备,适用于机房、养殖,配电(dian)箱、仓库、粮库、烤房等场合(he)。
控制方式:
①加热(re)除湿
当(dang)温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)低于设(she)(she)定(ding)的温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)下限时(shi),控(kong)制(zhi)(zhi)器内(nei)部(bu)温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)继电器接通(tong),加(jia)(jia)热(re)设(she)(she)备(bei)开(kai)始(shi)加(jia)(jia)热(re),当(dang)达到设(she)(she)定(ding)的温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)上(shang)限时(shi),控(kong)制(zhi)(zhi)器内(nei)部(bu)温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)继电器断开(kai),加(jia)(jia)热(re)设(she)(she)备(bei)停止(zhi)加(jia)(jia)热(re)。例如设(she)(she)定(ding)温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)上(shang)限为26.0℃,温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)下限为25.0℃,当(dang)环境(jing)温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)低于25.0℃时(shi),控(kong)制(zhi)(zhi)器内(nei)部(bu)温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)继电器接通(tong),加(jia)(jia)热(re)设(she)(she)备(bei)开(kai)始(shi)加(jia)(jia)热(re)。当(dang)温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)高于26.0℃时(shi),,控(kong)制(zhi)(zhi)器内(nei)部(bu)温(wen)(wen)(wen)(wen)度(du)(du)(du)(du)继电器断开(kai),加(jia)(jia)热(re)设(she)(she)备(bei)停止(zhi)加(jia)(jia)热(re)。
当(dang)湿(shi)度(du)高于(yu)设(she)定的湿(shi)度(du)上限(xian)时(shi),控(kong)(kong)制器内部湿(shi)度(du)继电(dian)器接通,风机等除湿(shi)设(she)备开始(shi)(shi)运行(xing),当(dang)达到湿(shi)度(du)下限(xian)时(shi),控(kong)(kong)制器内部湿(shi)度(du)继电(dian)器断开,风机等除湿(shi)设(she)备停(ting)止运行(xing)。例(li)如设(she)定湿(shi)度(du)上限(xian)为75.5%,湿(shi)度(du)下限(xian)为65.5%。当(dang)环(huan)境湿(shi)度(du)高于(yu)75.5%时(shi),风机等除湿(shi)设(she)备开始(shi)(shi)运行(xing),低(di)于(yu)65.5%时(shi),,风机等除湿(shi)设(she)备开始(shi)(shi)运行(xing)。
②加(jia)热加(jia)湿 智(zhi)能
当温(wen)度(du)低于设(she)定的温(wen)度(du)下限时,控制(zhi)器(qi)(qi)(qi)内(nei)部温(wen)度(du)继(ji)电(dian)器(qi)(qi)(qi)接通(tong),加热(re)(re)设(she)备开始加热(re)(re),当达(da)到设(she)定的温(wen)度(du)上限时,控制(zhi)器(qi)(qi)(qi)内(nei)部温(wen)度(du)继(ji)电(dian)器(qi)(qi)(qi)断开,加热(re)(re)设(she)备停止加热(re)(re)。
当(dang)湿(shi)(shi)(shi)(shi)度低于设定的湿(shi)(shi)(shi)(shi)度下限时(shi),控制器(qi)内部湿(shi)(shi)(shi)(shi)度继电器(qi)接通,加(jia)湿(shi)(shi)(shi)(shi)器(qi)等(deng)加(jia)湿(shi)(shi)(shi)(shi)设备开始运行,当(dang)环境(jing)湿(shi)(shi)(shi)(shi)度达到湿(shi)(shi)(shi)(shi)度上限时(shi),控制器(qi)内部湿(shi)(shi)(shi)(shi)度继电器(qi)断开,加(jia)湿(shi)(shi)(shi)(shi)器(qi)等(deng)加(jia)湿(shi)(shi)(shi)(shi)设备停止运行。
③降温(wen)除湿
当温(wen)度(du)高于(yu)设(she)定的温(wen)度(du)上(shang)限时,控(kong)制(zhi)器内部温(wen)度(du)继(ji)电器接(jie)通(tong),风机等降温(wen)设(she)备开始工作,当达到设(she)定的温(wen)度(du)上(shang)限时,控(kong)制(zhi)器内部温(wen)度(du)继(ji)电器断开,风机等降温(wen)设(she)备停止工作。
当(dang)湿(shi)度(du)高于设(she)定的湿(shi)度(du)上限(xian)时(shi),控(kong)制(zhi)器内部湿(shi)度(du)继电(dian)器接通,风机(ji)等除(chu)湿(shi)设(she)备开始运行,当(dang)达到湿(shi)度(du)下限(xian)时(shi),控(kong)制(zhi)器内部湿(shi)度(du)继电(dian)器断开,风机(ji)等除(chu)湿(shi)设(she)备停止运行。
④降温加湿
当(dang)(dang)温(wen)度高于设(she)(she)定的(de)温(wen)度上限(xian)时,控制器(qi)内(nei)部温(wen)度继电器(qi)接通,风机等降温(wen)设(she)(she)备开始工(gong)作,当(dang)(dang)达到设(she)(she)定的(de)温(wen)度上限(xian)时,控制器(qi)内(nei)部温(wen)度继电器(qi)断开,风机等降温(wen)设(she)(she)备停止工(gong)作。
当(dang)湿(shi)(shi)(shi)(shi)度低于(yu)设定(ding)的湿(shi)(shi)(shi)(shi)度下限时,控(kong)制器(qi)内(nei)部湿(shi)(shi)(shi)(shi)度继电器(qi)接通,加(jia)(jia)湿(shi)(shi)(shi)(shi)器(qi)等加(jia)(jia)湿(shi)(shi)(shi)(shi)设备开始运行(xing)(xing),当(dang)环境湿(shi)(shi)(shi)(shi)度达到湿(shi)(shi)(shi)(shi)度上限时,控(kong)制器(qi)内(nei)部湿(shi)(shi)(shi)(shi)度继电器(qi)断开,加(jia)(jia)湿(shi)(shi)(shi)(shi)器(qi)等加(jia)(jia)湿(shi)(shi)(shi)(shi)设备停止运行(xing)(xing)。